Art. 95 - Additional Deductions allowed by the Suez
Canal Authority :
The SCA allows the following sSEAPACEs to be included in the
deductions specified in Art. 12 of the Regulations for the Measurement of Tonnage,
provided the deductions do not, in the aggregate, exceed 5 percent of the gross tonnage. and subject to the condition that
they are clearly and permanently marked so as to show the purpose to which they are
exclusively appropriate:
A - SSEAPACEs for the exclusive use of officers,
engineers and crew :
- Master's accommodation.
- Officer's smoking room.
- Chief engineer's and Chief officer's dayrooms and/or
offices.
- Doctor's and dentist's cabins (if they are occupied by the
doctors and dentists for whom they are intended).
- Consulting rooms.
- Hospital.
- Infirmary.
- Surgery of operating room.
- Chemist's laboratory.
- Cabins of wireless operators (if utilized).
- Stewards cabins (if the stewards are solely employed for the
officers, engineers or crew).
- Cabins of the engineers storekeepers and water tenders.
- Mess rooms. (No deduction is allowed for officers mess room
in vessels having passenger accommodation which are not also provided with a passengers
mess room).
- Bath-rooms. (With the exception of such bathrooms as are
available for passengers when no bath-room for their exclusive use is provided)
- Lavatories.
- Library.
- Bar.
- Gallery, cook-house.
- Pantry
- Scullery,
- Bakery (only on vessels having no passenger accommodation).
- Laundry.
- Drying room.
- Heating boilers.
- Refrigerating machinery (excluding cold storage rooms and
store rooms).
- Distilling apparatus.
- Disinfecting apparatus.
- Wardrobes, oilskin and lifebelt lockers.
- Ventilators (utilized neither for passengers or cargo).
- Night watchmen accommodation (provided these men are signed
on as crew and are not employed in connection with passengers or cargo).
- Accommodation
of fire fighting personnel.
- Domestic water pump rooms.
- Switchboard
lockers.
- Transformer
rooms.
B - Navigation sSEAPACEs (if above the uppermost deck)
- Chart house.
- Master's spare room on the bridge (especially on warships).
- Searchlight sSEAPACEs.
- Submarine telephone sSEAPACEs.
- Direction finder sSEAPACEs.
- Sounding sSEAPACEs.
- Gyro compass sSEAPACEs.
- Wireless telegraphy sSEAPACEs.
- "Radar" sSEAPACEs (exclusively used for navigational
purposes.
- Lamp room (if only containing signal lamps)
- Lookout houses.
- Emergency generators.
- Emergency compressors (if used exclusively in case of
accident for pumping out water and not for any commercial purposes).
- Switchboard lockers.
- Transformer rooms.